Canister load cell cross-reference & geometry comparison
Compare canister, pancake, beam and S-type load paths. Review replacement geometry, cups, outputs and approvals before selecting an alternative.
Canister load cell replacement review requires H₁, H₂, Ø and R
A replacement must be checked as an assembled system, including end-spigot diameter, cable exit centerline and mandatory rocking direction: bare height H₁, total seated height H₂ with both cups, body diameter, spherical end radii, retention hardware and cable clearance. Add rated output, bridge resistance, excitation, wiring and the exact approval variant. Brand and capacity alone cannot establish interchangeability.
Canister load cell versus pancake, beam and S-type geometry
Canister columns offer a compact axial compression load path; rocker versions accommodate controlled deck movement. Pancake designs can suit low headroom and particular stiffness requirements. Beam cells can cover industrial weighing at capacities extending well beyond 10 t; S-type designs can support tension/compression fixtures. There is no universal 30 t boundary where other geometries cease to work.
Canister load cell retrofits with proprietary digital systems
Flintec RC3/RC3D, HBK C16A/C16i, Zemic BM14G/HM14H1, Rice Lake, Anyload and AmCells are reference-identification requests. Mettler Toledo POWERCELL PDX and SLC820 mechanical-retrofit enquiries need a separate electronics and indicator review. Mechanical fit never implies compatibility with a proprietary digital network. Brand names identify their respective owners; no affiliation or authorization is implied.
| Reference family | Geometry to provide | Signal / integration check | CLC review route |
|---|---|---|---|
| Flintec RC3 / RC3D | Ø, H₁, H₂, R₁/R₂, cup set | mV/V & Ω or digital protocol | CLC-RCK / CLC-DIG |
| HBK / HBM C16A / C16i | Full mount drawing and rotation stop | Analog wiring or proprietary digital interface | CLC-RCK / CLC-DIG |
| Zemic BM14G / HM14H1 | Exact suffix, capacity, cup and height | Sensitivity, bridge resistance, cable | CLC-RCK |
| Rice Lake / Anyload / AmCells | Manufacturer model and assembly revision | Indicator, excitation and approval variant | CLC-RCK / CLC-CMP |
| POWERCELL PDX / SLC820 | Mechanical retrofit drawing and mounts | Proprietary network compatibility not established | Separate system conversion review |
| 2300 flange-mount column | Manufacturer and flange/bolt drawing | Rated force, output and calibration range | CLC-1000T |
Canister load cell reference dimensions: Flintec RC3
Original-manufacturer reference only, from RC3 datasheet A48-Rev12-GB, page3. These are bare-cell dimensions; no CLC equivalence or cup-stack height is established. The original drawing calls its full bare height H1 and its top-to-cable-centerline dimension H2. Our worksheet uses Htotal/H2 for the assembled stack, so do not transfer symbols without reading the drawing.
| Original capacity | Bare height (OEM H1) | Body OD (OEM D2) | Load spigot Ø (OEM D1) | Maximum lateral displacement (OEM Smax) | Total height with cups |
|---|---|---|---|---|---|
| 15 t | 89 | 69 | 28 | 4.5 | Assembly drawing needed |
| 30 t | 140 | 81 | 39 | 10.5 | Assembly drawing needed |
| 40 t | 150 | 81 | 39 | 10 | Assembly drawing needed |
| 50 t | 178 | 99 | 44 | 9 | Assembly drawing needed |
| 100 t | 178 | 120 | 62 | 11.5 | Assembly drawing needed |
Use the original drawing for mandatory main rocking direction (MRD), top/bottom orientation and stepped-end dimensions H3–H6. Equal 178 mm bare heights on 50 t and 100 t cells do not mean equal cup interfaces. This table does not establish legal-for-trade approval: the source lists 100–300 t under GP; approval variants and capacity limits must be checked separately.
Download CLC assembly checklist| Geometry | Load path | Good starting point | Integration constraint |
|---|---|---|---|
| Rocker column | Axial compression; restoring geometry | Weighbridges, rail decks and silo modules | Matched cups, travel and restraint design |
| Flat / flanged canister | Axial compression | Heavy presses, jacks and static load tests | Alignment, bearing stiffness and contact stress |
| Pancake | Low-profile axial force | Limited vertical headroom and test fixtures | Mounting stiffness and eccentricity limits |
| Shear / bending beam | Shear or bending strain | Platform, tank and industrial weighing | Mounting geometry and lateral-force isolation |
| S-type | Tension and/or compression | Suspended or inline test arrangements | Clevis/rod-end alignment and overload control |
Canister load cell questions that affect the assembly
Is CLC-RCK a verified Flintec RC3 or HBK C16A drop-in replacement?
No universal equivalence is claimed. Provide the complete original model, capacity, assembly drawing, output, indicator and approvals. A specific alternative can be quoted after the interfaces are reviewed.
What is the 2300 high capacity flange mount column load cell enquiry?
Treat 2300 as a reference series identifier. Share its manufacturer and exact drawing revision; it is not an independent dimensional standard or a verified CLC equivalent.
Canister load cell reference documents
Original-manufacturer and metrology references explain the engineering principles. They do not certify a CLC configuration.
Self-restoring column design, model-specific dimensions and surge-arrestor features. Refer to the exact capacity and drawing revision.
Self-restoring rocker pins, rotation stop, capacity and protection variants; these are original-manufacturer specifications.
Load introduction and restoring geometry; assembly design still governs lateral restraint.
ASTM E74 and ISO 376 instrument-calibration methods; a five-point test alone does not establish compliance.